Products
« Category overview | Thermal after-burning - TNV
Thermal after-burning - TNV(Article number: 863)
|
Memo Inquiry |
||||||
Manufacturer: | Keratek | ||||||
---|---|---|---|---|---|---|---|
Type: | x | ||||||
Year of construction: | - | ||||||
Description: | Burning cycles per annum: 120 fires Fuel: Natural gas Furnace atmosphere: Oxidizing Waste gas treatment: TNV for the waste gases deserting the stove less than approx. 600 °C, about this to the by-pass directly into the chimney under addition of fresh air to the lowering of the flue gas temperatures on approx. 350 °C. Presentation data of the TNV: Waste gas volume of the TNV = approx. 1000 Nm³/h Fuel = natural gas 10 kWh/Nm³ Max. 60 = Nm³/h fuel requirement max. C content to TNV = 30 mg/Nm³ Burner performance installed: 600 kW TNV Chimney: Steel fireplace approx. 790 mm Ø, height of approx. 18 m 1000 mm Ø, with rain hood The waste gases of the kiln reach an inside isolated waste gas collecting pipe of 1000 mm of inside diameters. At an end is a fresh ventilation flap ange with engine which is regulated by a temperature regulation-took, if the stove does not have to be driven by the TNV any more (T=600°C). On the waste gas collecting pipe is a waste air chimney stack ange which becomes durchströmt over a change flap in the cooling phase-took. The waste gas is vacuumed by the waste gas collecting line in the direction of the TNV plant. A by-pass is in front of the TNV plant to go round the TNV combustion chamber. The waste gas is, at higher temperatures in the by-pass at the combustion chamber past driven through the TNV plant at oven temperatures less than approx. 600°C. Vertrieb/ |
||||||
Quantity: | 1 pc | ||||||
Data in accordance with manufacturer | |||||||